AMD Ryzen 7 1800X @ Stock

Temperature (Tdie)Arctic LF 240: 59,5Arctic LF 24059,5Cooler Master ML 240 Lite: 59,5Cooler Master ML 240 Lite59,5Noctua D15: 62Noctua D1562Cryorig H5 Ultimate: 64,9Cryorig H5 Ultimate64,9Scythe Mugen 5 Rev.B: 66,1Scythe Mugen 5 Rev.B66,1Noctua L12S push-pull: 66,9Noctua L12S push-pull66,9Noctua L12S stock: 69,5Noctua L12S stock69,5Arctic Freezer 12: 71,5Arctic Freezer 1271,5Noctua L9a: 75Noctua L9a75083

Prikazane temperature T(die), tj. za 20°C su niže od T(ctl). Mugen 5b je samo za 1.2 °C slabiji od H5 Ultimate hladnjaka i to je bilo i za očekivati. Ventilator mu radi na 100 okretaja niže, ali je zbog toga i velika 2 dB tiši.

AMD Ryzen 7 1800X @ 4.0 GHz

Temperature (Tdie)Arctic LF 240: 79Arctic LF 24079Cooler Master ML 240 Lite: 80,3Cooler Master ML 240 Lite80,3Noctua D15: 85Noctua D1585Cryorig H5 Ultimate: 88,5Cryorig H5 Ultimate88,5Scythe Mugen 5 Rev.B: 90,5Scythe Mugen 5 Rev.B90,50100

Kod overclockinga se razlika nešto povećala, na 2°C. Temperature oko 90°C su već vrlo visoke i za uspješno hlađenje preporučujemo push-pull kombinaciju, ili kombinaciju nešto nižeg takta i napona. Za sve ispod 1800X će i H5 Ultimate i Mugen 5b biti vrlo dobri.

Buka

BukaScythe Mugen 5 Rev.B @ Max.: 45Scythe Mugen 5 Rev.B @ Max.45Arctic LF 240 @ Max.: 46Arctic LF 240 @ Max.46Cryorig H5 Ultimate @ Max.: 47Cryorig H5 Ultimate @ Max.47Cooler Master ML 240 Lite @ Max.: 49Cooler Master ML 240 Lite…49Noctua D15 @ Max.: 50Noctua D15 @ Max.50055

45 dB je niska vrijednost buke i ventilator je u radu vrlo tih.